← Back to Engineering Website
How to read the report

Health report metrics

Overall status
The highest applicable status from the individual checks. Insufficient data alone does not make a float concerning.
Pump runtime vs fleet average
The float's recent average runtime divided by the fleet average, expressed as a percentage. Over 130% is Watch and over 155% is Concern.
Quiescent voltage
The latest quiescent-voltage reading. Values below 10 V are Concern.
Humidity
The latest humidity and its comparison with the float's own average. If either value is below 1%, the comparison is skipped.
Buoyancy position
The average of the last two park or deep-profile readings divided by that float's absolute average. It is not a fleet comparison.
Connection failure estimate
Estimated failed connections divided by connection attempts. Under 20% is Good, 20–50% is Watch, and over 50% is Concern.
Time on surface
The latest transmission duration in seconds. This is informational only.
Days since latest report
More than 10 days is Watch and more than 30 days is Concern. More than 100 days turns the link red.
Float reports

Available health reports

Good Watch Concern Over 100 days
Loading reports...